In preparation for my first table saw and in order to initiate my garage's transformation into a proper shop space, I need to do a little work. Task #1 involves electrical. Here is what I am going to do:
* 60-100A subpanel w/60A main breaker fed by 6/3 copper wire
from my 200A main panel with subpanel's common ground hooked
up at main panel
* 2 30A 220V outlets, each on a separate breaker using 10/3 Romex
* 2 20A circuits for various outlets using 12/2 Romex, separate breakers
each
* 1-2 15A lighting circuits using 14/2 Romex
I'll have to run the 6/3 wiring through a trench about 4 feet long, as well as along an exterior wall. In this case, should I run single stranded wire (3 #6 and 1 #8-10) through grey conduit?
Thoughts and comments appreciated! Don't hesitate to label me captain obvious either.
Take care,
JT