• Recent Articles

  • Hottest Threads

    Dave Anderson NH

    Time for some levity

    Thread Starter: Dave Anderson NH

    With all of the negativity and political stuff going on with the Covid-19 virus it is time to look at the humorous side of things. Feel free to add more, but keep it clean or it will be deleted.

    Last Post By: William Lessenberry Yesterday, 6:05 PM Go to last post
    jack duren

    Professionals given no credit on forums..

    Thread Starter: jack duren

    Says it all.. I was yelled at for two years in 1983-1985. Got hurt in 1985 on the table saw . Changed jobs and finally work myself up to a foreman..Did this for 37 years. Was on another forum and was told they do not recognize professionals . What does that mean? I did kitchen cabinetry for...

    Last Post By: Edward Weber Yesterday, 1:58 PM Go to last post
    Brian Elfert

    Is the cost of anything not going up?

    Thread Starter: Brian Elfert

    Inflation may be less, but everything still seems to be going up in price. Verizon just increased my cell phone bill by $5 per month. My monthly bills have gone up by at least $200 per month since 2020. That doesn't include the high cost of food. It doesn't help that my wages are 15% less than...

    Last Post By: Dave Zellers Today, 12:29 AM Go to last post
    Josh Baldwin

    Best Shaper Under $5000?

    Thread Starter: Josh Baldwin

    Hey everyone I have a nice router table, but I've been thinking of upgrading to a shaper. I'm thinking 5hp would be ideal, but I'm not sure what other features exactly I should be looking for. There are 3 that seem like a good fit and I'm hoping to get some feedback based on their specs and/or...

    Last Post By: Josh Baldwin Yesterday, 10:16 PM Go to last post
    Edward Weber

    Are your tools dangerous?

    Thread Starter: Edward Weber

    Do you consider tools as dangerous? https://www.popularmechanics.com/home/tools/how-to/g2394/10-workshop-tools-that-can-kill-you/ I came accross this article and it struck me, that I don't consider my tools as dangerous or not. To me it's just a tool. Sure, some tools can cause greater injury...

    Last Post By: Tom Trees Yesterday, 11:52 PM Go to last post
    Connie Freitas

    Router Bit won’t budge.

    Thread Starter: Connie Freitas

    How do I get this router bit out of here? Tug as might, it won’t come out. I tried some WD40 recently but it didn’t help at all. I’ve since read that I’m not supposed to use a lubricant of any kind. So, what do I do please?

    Last Post By: George Yetka Yesterday, 3:01 PM Go to last post
  • Lighting the Small Workshop - by Jack Lindsey

    Lighting the Small Workshop
    By Jack Lindsey

    "Ten years have passed since I wrote the Fine Woodworking article on lighting the small shop," Jack Lindsey explains, but much has changed. Jack comprehensively explores lighting a hobbyist or small industrial shop, drawing on over 25 years of professional lighting experience, covering topics such as fixture and ballast selection, lamp life, and color when employing fluorescent lamps.

    Introduction

    Ten years have passed since I wrote the Fine Woodworking article on lighting the small shop. While the principles it contained remain valid, there have been changes in lamps and ballasts resulting from technological advances, and legislative mandates have outlawed some of the most popular lighting products. Magnetic ballasts for most lamps are being phased out, and the mainstay of fluorescent lamps, the T12’s, are meeting the same fate. Some of the common general service incandescent lamps have also been outlawed in favor of more energy efficient fluorescent and LED lamps. The replacement products are for the most part more energy efficient although in some instances they are inferior in terms of performance and generally have a much higher first cost. We have no choice but to use them, and choosing the ones we use carefully can result in better performance and lower overall costs.


    This article will focus on lighting the hobbyist or small industrial shop with ceiling heights of 16’ or less using commonly available T8 lamps, and strip or industrial type fixtures. The design method used in this article may also be used for T5 HO lamps with the caveat that they are several times brighter than T8’s and may cause objectionable direct glare if located within the field of view. Their use should be confined to shops with high ceilings. The minimum height will vary with the size of the shop, with large shops presenting the greatest potential for glare since more ceiling area will be within the field of view as the size of the shop increases. As a general rule I prefer to see them at a minimum height of 14’. Be aware that T5 HO lamps are currently about 5 times the cost of T8’s, and fixtures cost almost twice as much. This is somewhat offset by the need for fewer lamps and fixtures. If you are considering using these lamps I suggest a trip to your local big box home improvement store to see them in operation. If you are satisfied that the brightness is acceptable the next step is to determine how many fixtures will work in your shop, and compare the economics between T5 and T8 systems.

    Twenty eight watt T5 lamps are not included since their performance characteristics are similar to T8’s but they are significantly higher in cost. HID lamps in wattages suitable for industrial use are very bright and should be mounted at heights of 18’ or more so they are not included. Light emitting diodes (LED’s) are an emerging technology and are also omitted.

    Over the years I have done many posts on this and other forums suggesting the installation of “x” number of fixtures spaced “y” feet apart, and you may have seen one or two where I explain some of the theory behind it. This article will differ in that it will enable the reader to easily determine the number of fixtures that are needed, and provide guidelines on how to lay them out in the space. It will contain some theory but concentrate on the mechanics so almost anyone can follow the blueprint to light a small shop. No one will come out of this a qualified lighting designer but that's not the objective. I’m just trying to improve on what can be done through trial and error, and try to combat some of the misconceptions about lighting that I see on a regular basis on the forums.

    We’ll start with some lighting terminology that will be needed as we progress through the steps to design your own lighting system. Then a brief discussion of how much light we really need based on the kinds of things we do in our shops and the age of our eyes.
    Then we’ll get into the meat of the subject: the lamps, ballasts, and fixture types that best meet our needs. We’ll talk about lamp characteristics, circuit types, lamp life, and color temperature and color rendering index. Electronic ballasts are now the norm but there are distinct differences between many of them. For the most part we are at the mercy of the fixture manufacturers since they select the ballasts they install but we do have the option of using another fixture if necessary. This article will discuss the important ballast characteristics that should be considered when we buy a fixture.

    There are many different kinds of fluorescent fixtures. Some are well suited for lighting our shops. Others are not. I’m not going to engage in a discussion of brand names but I will go over things to consider when picking a fixture. And we’ll concentrate on fixtures that are readily available through the big box retailers and lighting distributors.

    Finally, we will go through a simplified method of determining how many fixtures are needed using a method I developed and taught in my lighting classes to help contractors and lighting sales people come up with a preliminary number of fixtures to help qualify prospective customers. While the method isn’t precise it is sufficiently accurate for a small shop.

    Note that this discussion assumes that we will provide uniform illumination throughout the shop. Why do this instead of just lighting the work areas? Simple. Fluorescent fixtures tend to have a fairly wide distribution of light, space is usually at a premium so we locate machines close together, and we move machines periodically about the shop.

    The last step is laying out how the fixtures will be installed. Should they be installed in continuous rows or as individual fixtures? How far apart should they be? How close should they be to the walls? Should they be mounted directly to the ceiling or suspended?
    The article is arranged in sections, each covering an individual topic. If you already know how much light you want, what equipment to use, or how you want to light the space you can simply skip those sections and go directly to your area of interest.

    Dave Anderson, a Moderator of the forum, asked that I include my qualifications to write the article so here goes. I retired as a Senior Engineer from a major west coast electric utility where I specialized in lighting for over 25 years. My main responsibilities were providing assistance to commercial and industrial customers on lighting, training company personnel, and evaluating new lighting equipment. I taught evening classes in lighting design at a couple of community colleges and a course in Illumination Engineering at a state university, and wrote “Applied Illumination Engineering” which was used as a text for those classes. I also wrote a monthly column on lighting for Electrical Contractor magazine, and have authored and presented numerous technical papers on lighting to IEEE, IESNA, and AEE. I’ve served as an advisor to the California Energy Commission on the development of the lighting portion of their energy code and as a charter member of their Advance Lighting Professional Advisory Group. I am a Fellow of the Illuminating Engineering Society of North America and have served as President of that organization.

    Now, on to lighting our shops.

    FUNDAMENTAL LIGHTING UNITS AND RELATIONSHIPS

    Yeah, this is the boring part. When I took my first class in lighting we spent several hours going over terminology, definitions, and their relationships. I was bored to tears and spent most of that class period wishing I was fishing. It didn’t take long to realize, though, that it was going to be tough if I couldn’t comprehend the language of lighting. We’re only going to cover three basic units in this discussion though, so it won’t be too bad. And we’re going to discuss them in plain English, not scientific terms, so leave your physics books on the shelf.

    CANDELA The first building block is the “candela” (cd). It is the unit of luminous intensity and allows us to assign a number value to the brightness of a light. The higher the number, the brighter the light. An ordinary wax candle flame has an intensity of 1 candela when viewed from any angle. It is used in industry as a basis for many lighting calculations.

    LUMEN The lumen (lm) is the basic unit of a quantity of light. That’s not the technical definition but it’s pretty close and is a lot more understandable. The light output of a lamp is rated in lumens. The common 100 watt incandescent in your table lamp produces about 1750 lumens. Many 4’ T8 fluorescent lamps are rated at 2800 lumens.

    FOOTCANDLE The footcandle (fc) describes how much light is striking a surface. More light equals more footcandles. By definition one footcandle is equal to 1 lumen of light striking one square foot of surface area. The footcandle is being replaced by the SI unit of illuminance, the lux. One lux is equal to 1 lumen of light striking one square meter of surface area. A square meter is about 10 square feet so 1 fc is approximately 10 lux.

    The SI system has been slow to gain acceptance in the United States so this discussion will be based on footcandles and feet.


    Now let’s explore how these units are related and how we can use that knowledge to light our workshops. Let’s light a common candle and place it in the center of a plastic sphere that has a radius of 1 foot as shown in Figure 1. Now divide the sphere into one square foot areas and measure the amount of light striking each square foot. By definition that amount is one lumen. It is equal to the amount of light falling on an area of 1 square foot, all points of which are 1 foot away from the light source. Since our sphere has a radius of 1 foot it has a surface area of 12.57 square feet and our candle with an intensity of 1 cd produces 12.57 lumens. This helps put the light output of a lamp in perspective. It takes a lot of candles, about 139, to equal the light output of a 100 watt incandescent lamp.



    Figure 1. Relationships between candelas, lumens, and footcandles. When a light source of 1 cd intensity is placed in the center of a sphere with a 1 foot radius, 1 lumen of light will strike 1 square foot of surface area. This produces a lighting level of 1 footcandle.
    Courtesy of IESNA (Picture of candle added for clarity)


    HOW MUCH LIGHT DO WE NEED?

    Rather than spend several pages discussing the complexities of evaluating visual tasks and quantifying illuminance requirements based on age, the need for speed and accuracy in our work, or the influence of the reflective characteristics of the things we work on I’m simply going to give you my opinion based on over 25 years in the profession. Typical hobbyist and small commercial woodworking shops should be lighted uniformly to levels of 50 or 100 footcandles (fc). Fifty fc for shops with young workers (age 25 or less) where there are no difficult visual tasks like intricate carving, fitting of small precision parts, etc.

    For those of us over 25 or in shops with more detailed work as mentioned above I recommend 100 footcandles. If we are performing very difficult visual tasks like intricate carving additional light may be needed. This is typically provided by a small task light. The recommended values fall within recommendations published by the Illuminating Engineering Society of North America (IESNA) in their 2011 Lighting Handbook. Note that these are nominal values and a variation of 10 to 20% isn’t significant. Why? Because the human eye is an amazingly adaptable instrument. We can see at night in a parking lot under 1 fc or less or on a sunny mountain top with over 10,000 fc at high noon. Small variations in lighting levels are insignificant in terms of visual performance.

    FLUORESCENT LAMPS

    Unlike incandescent lamps which produce light by heating a thin tungsten wire filament to a very high temperature, fluorescent lamps don’t have a filament and operate quite differently. They consist of a glass tube that has had virtually all the air removed and small quantity argon, neon, or other specialized gas injected. Some metallic mercury is added, a wire coil called a cathode is inserted into each end, and the tube is sealed. See Figure 2. The internal pressure is very near a vacuum so the mercury is primarily in a gaseous state, with molecules of mercury floating independently within the tube.





    Figure 2. Cutaway of a typical fluorescent lamp showing component parts.
    Courtesy of IESNA


    While the cathode may resemble an incandescent filament its function is quite different. It acts as a terminal for an electric arc that passes through the tube. In operation electrons in the arc stream collide with electrons in the mercury atoms causing some of them to be temporarily displaced. When they jump back to their proper locations they give up the energy they took on from the collision. A little of that energy is in the form of visible light but most of it falls in the ultraviolet region, 253.7 nanometers for those with inquiring minds. Figure 3 illustrates this sequence of events.

    The cathodes are coated with an emission material that provides the electrons for the arc stream. As the lamp operates the material is boiled off the wire so the supply of electrons is continuous. When all of the material is evaporated from either cathode the arc cannot be maintained and the lamp fails.

    The inside of the tube is coated with a powder, called a “phosphor”, that converts the UV energy to visible light. Different phosphors are used to produce different colors of light, and the process is much more efficient that heating a wire. Figure 3 illustrates this sequence of events.



    Figure 3. Principle of operation of a fluorescent lamp. An electron in the arc strikes an electronin the mercury atom causing it to jump to a higher energy level. When the electron jumps back to its original level the energy it took on in the collision is released in the form of ultraviolet radiation which strikes the phosphor on the inner surface of the tube and excites it. This produces visible light. Courtesy IESNA

    Why is all this important? Because it will be used later in the discussions of color and ballasts.

    This discussion will focus on T8 lamps. The “T” indicates that it is a tubular lamp and the “8” denotes the diameter in 1/8ths of an inch so a T8 is 1” in diameter. Quite a bit smaller than the 1 ½” T12 lamp that was the industry standard for decades. They are available in lengths ranging from 2’ to 8’ for general lighting however shorter lengths are made for some specialized applications. Four foot lamps are the most common and are preferred for the typical hobbyist or small industrial shop for two good reasons: they are lower in cost, and much easier to handle than 8’ lamps – especially when atop an 8’ or 10’ ladder.

    COLOR

    The color temperature and color rendering index of a fluorescent lamp are probably the two most discussed and least understood lighting topics discussed on the forums. They are interrelated and will be discussed together.


    Color Temperature

    The visual color of a light source is described by its color temperature. Imagine a bar of steel. At room temperature it is a dull grey. Now imagine that the bar is placed in a blacksmith’s furnace. As the temperature of the bar rises it begins to change color. First a dull red, then as more heat is applied it progresses to a bright cherry red, then orange, yellow, and finally a bluish white. If we measure the temperature of the bar at any of the colors we can then describe the color of the bar in terms of its temperature, and each and every time we heat the bar to that specific temperature it will appear to be the same color. For example, if we heat the steel to a temperature of 4941 degrees F it will appear to be a warm, soft white with an almost imperceptible tinge of yellow. This will be about the color of a 200 watt incandescent lamp or a 3000K fluorescent.

    The example, while accurate for purposes of understanding, isn’t scientifically correct. In practice we use a theoretical device called a blackbody radiator instead of a bar of steel. The blackbody will perfectly absorb and then reradiate all energy that strikes it. An incandescent filament almost perfectly matches the blackbody within the visible portion of the spectrum so we have visual basis for comparison.

    Note in the example I cited a temperature of 4941 Degrees F for the bar yet compared it to a 3000K fluorescent lamp. That’s because we don’t use the F scale to describe color temperature. We use the Kelvin scale, also known as the Absolute scale. Note that while the temperature in F or C is stated in degrees the temperature for the K scale is stated in Kelvins, not degrees Kelvin. The Kelvin scale uses the same gradients as the Celsius scale but has its zero point at -273C. The two temperatures, 4941 F and 3000K are the same. Figure 4 shows a comparison of the three scales.




    Color temperature also describes the visual impression of the space in terms of warmth or coolness. A 3000K lamp imparts a feeling of warmth while a 4100K lamp is cool. Temperatures of 5000K and above tend to psychologically feel cold and sterile.

    Color Rendering Index

    Color temperature only tells part of the story about how the light from a lamp will make an object look. Unfortunately there isn’t a perfect way to describe it but we do have a system that helps. It isn’t ideal but it’s all we have. It’s called “color rendering index” and it describes how well the spectral distribution of the lamp compares to that of a blackbody radiator, typically at eight specific colors. As differences widen between the test lamp and the blackbody the CRI will begin to decrease. In general a higher CRI will provide better color rendering. It is important to note that the lamp and the blackbody must operate at the same color temperature.

    Comparisons of CRI’s between lamps of different color temperatures will be meaningless. For example, incandescent lamps have a CRI of 100 throughout their range of operating temperatures from dimmed to full brightness yet their ability accurately render colors varies widely as the color temperature changes. At 1800 K the lamp produces mostly red light so reds look great and blue colors will be washed out. Increase the temperature to 3000K and blues will look much better and reds will also good. At 4100K blues improve but reds begin to wash out.

    Selecting a lamp color for your shop is a matter of personal preference and how much you are willing to spend. There are no right or wrong answers. Some stores have displays of several lamp colors and they can be helpful. If you can’t find a display and don’t already have a preference, 3500K is somewhat neutral and not a bad place to start.

    Note that there has been no discussion of the screw in compact lamps. They have been purposely omitted because they are simply not a viable light source for lighting an entire shop. If you have a need for supplemental light at a specific location or are looking for a screw in replacement for an incandescent lamp they may be fine, but not for lighting an entire shop. Compared to a T8 they are less efficient, have a shorter life, more expensive.

    BALLASTS

    Once an electrical arc has been initiated in a fluorescent lamp, the lamp exhibits a negative electrical resistance characteristic: the resistance to current flow through the lamp decreases as the current increases. This “run-a-way” current would destroy the lamp in a few seconds if allowed to continue. An auxiliary device, called a ballast, is required to prevent this condition. In addition to limiting current the ballast provides the proper voltages to start and operate the lamp.

    Most older ballasts, referred to as “magnetic”, contain a current limiting transformer, a power factor correction capacitor, and a thermal safety switch. The transformer consists of coils of copper or aluminum wire wound around a steel core to alter the output voltage. These coils have resistance therefore some electrical energy is lost in the form of heat. This is bad since the heat costs money on your power bill, and excessive heat shortens the life of the ballast, particularly when it is enclosed in a fixture.

    Magnetic ballasts for most lamps have been eliminated by legislative mandate and have been replaced with ballasts using electronic components to perform the required functions. There were some problems with them during their early days in the 1980’s and ‘90’s but those have been resolved and most current electronic ballasts are highly efficient and very reliable. They have lower internal power losses since they do not utilize transformers. Another, seldom discussed advantage of electronic ballasts is they generally drive lamps at frequencies of 12 kHz or higher which increases the efficiency with which the phosphors produce light.

    Rapid Start vs Instant Start Ballasts

    There are many different types of electronic ballasts on the market and they vary widely in performance characteristics. As previously mentioned at the beginning of the discussion of fluorescent lamps, the cathodes which serve as terminals for the arc contain an emission material to provide electrons for the arc stream. These electrons must be heated to boil them off the cathodes. This can be done in either of two ways: independently heating the cathode by continuously applying a low voltage to it, or by using a high voltage to blast electrons off the coils and then relying on heat created by the arc stream to maintain the cathode temperature. The first method is known as “rapid start” and the second as “instant start”. Rapid start ballasts provide a gentler boil off of electrons compared to instant start so lamps tend to last longer when operated in the rapid start mode. The downside is that the independent cathode heating uses power that adds to operating costs so if all other factors are equal a rapid start system will cost slightly more to operate. There are premium instant start ballasts available that employ circuits to soft start lamps and significantly extend lamp life.

    Unfortunately we have no control over the specifications for the ballast in the fixtures we buy so we take what we can get, estimate the number of fixtures we need based on generalities, and pay the power bill. Fortunately, for a small shop, that produces sufficiently accuracy for the design process and the differences in cost are usually insignificant.

    One final thought on ballasts. Many of the inexpensive shop lights use the minimum components needed to operate a lamp to keep costs down. Because of this they may significantly shorten lamp life and may fail prematurely. I don’t recommend them.

    LAMP LIFE

    The life of a fluorescent lamp ends when all of the emission material, previously discussed, evaporates from one of the cathodes. This is governed by the ballast type and quality, and the number of operating hours each time the lamp is started. Frequent starts and short burning cycles shorten life while longer cycles extend it. Most ballasts used in industrial grade and medium to high quality consumer products can be expected to drive lamps within the lamp manufacturer’s specifications. Inexpensive ballasts used in low priced shop fixtures may not provide the correct voltage and current characteristics and result in low light output and short lamp life.

    Rated life doesn’t mean that each lamp will last that long. It means the point at which 50% of the lamps in a large sample will have failed and the remaining 50% will still be in service. Failures can be expected to begin at 40% of rated life and accelerate to 50% failures at rated life. Theoretically for each lamp that fails early another lamp will last a corresponding time past rated life.

    Note that I haven’t put an hour figure on rated life. That’s because it varies greatly by 4’ or 8’, instant start vs. rapid start circuitry, premium circuitry in the ballast, and the number of hours the lamp is operated per start. In general 4’ lamps have longer lives than 8’ lamps, rapid start lasts longer than plain instant start, and premium instant start may last the longest. Unlike the days when I entered the lighting profession and you simply went by the single number in the lamp catalog it’s now necessary to consult lamp and ballast catalogs for accurate information. If you are buying a fixture off the shelf at a big box retailer just assume 20,000 hours for a 4’ lamp and 15,000 for the eight footer and check the manufacturer’s literature if you want a more accurate number. This assumes operation for 3 hours per start. Life will be shortened if you turn them off more frequently and extended with longer operating hours. Sorry to be so vague but we would have to append a lot of catalog pages to the article to cover all the possibilities.

    FIXTURE SELECTION

    There are two fixture types that are well suited for our shops: strips and industrials. A strip is simply a white channel that contains the ballast, is equipped with a white cover, and has sockets to hold the lamps. It is the least expensive and is well suited for mounting directly to a finished ceiling. It is recommended that the ceiling be painted a light color, preferably white, to reflect light down to the work area.
    An “industrial” is a strip fixture that is equipped with a reflector to direct light downward. It is recommended for use on unfinished ceilings or when fixtures are to be suspended below the ceiling. The reflector may be white painted metal or specular aluminum. Some reflectors have slots, called “apertures” that allow air to flow past the lamps and through the fixture. The air flow helps keep lamp and fixture surfaces cleaner by carrying dust in the air out of the fixture instead of letting it build up. It also reduces heat buildup around lamps and in the ballast compartment. This increases light output and extends ballast life. The apertures also allow some light to pass through to illuminate the ceiling and help reduce the psychological feeling of working in a cave. They are generally a better choice than reflectors without apertures.

    Other fixture types that I have seen recommended on forums include “wraps”, “troffers”, and other office type fixtures. A wrap is simply a strip fixture that has a plastic lens enclosing the lamps. Troffers are the recessed fixtures we see in most offices and some retail establishments. They are equipped with a lens or louvers to shield lamps from direct view and direct light in specific directions. Neither type is recommended for use in woodworking shops since the lens adds two surfaces, the inside and the outside, that will accumulate dirt and decrease fixture performance. The lens also traps heat which can adversely affect lamp performance. Typical fixtures are shown in Figure 5.




    Figure 5. Typical fixtures. From left to right: industrial with reflector, strip, and wrap.
    Strips are used when mounted directly to a light colored ceiling. Industrials are best
    for mounting to joists when there is an unfinished open ceiling, or when fixtures
    are suspended from higher ceilings. Wraps are not recommended for shops due
    to dirt buildup on the plastic lens.
    Courtesy IESNA

    A final thought on fixtures. You may be tempted to use a strip instead of an industrial with a reflector if your shop construction calls for the industrial. Yes, the strip is lower in cost but it won’t perform well unless it is mounted on a white painted ceiling.


    ESTIMATING HOW MANY FIXTURES ARE NEEDED

    The first step is to decide what lighting level you want. As previously noted I recommend 100 footcandles unless you are under the age of 25 and will be performing work that is not demanding and is easy to see. If that’s the case you may get by with 50 fc or less. Since 100 fc is a more common recommendation that is the value we will use in this example.

    Next let’s calculate how many lamps will be needed using the simplified rule of thumb method which says that 50% of the fixture lumens will reach the work plane when installing open fixtures like strips or industrials in rooms with fairly light colored ceilings and walls. If using enclosed fixtures, which I generally don’t recommend for shops, the figure is closer to 40%. Why only 50%? There are several reasons. First, not all of the light gets out of the fixture. Some hits fixture surfaces where it is absorbed and lost. Some light hits the walls and other building surfaces where it, too can be absorbed. That loss can easily be 25% or more. And over time the light output of a fluorescent lamp decreases due to a deterioration of the light producing phosphors and a buildup of tungsten which evaporates from the cathodes and deposits on the bulb wall. On average we can expect the typical T8 system to lose 10% to 15% of its initial output due to depreciation within the lamp.

    Another significant loss occurs from the buildup of dirt on fixture and lamp surfaces. If you doubt this simply wipe a lamp that has been operating in a workshop for a year or more with a white cloth. Over time you can easily lose an additional 10% to 20% even in a relatively clean shop. Dirt accumulation on walls and ceilings accounts for additional losses.

    Now that we have accepted that we are going to lose light over time let’s see how many fixtures are needed. For this example let’s assume a 1500 square foot shop with a 10 foot ceiling painted white, and white walls.

    The footcandle was previously defined as lumens of light per square foot. To provide 100 footcandles we need 100 lumens per square foot times 1500 square feet, or 150,000 lumens at the work surface. Since only half of the lumens on the ceiling make it down to the work surface we need twice as many on the ceiling, or 300,000 lm. Assuming a 32w T8 lamp rated at 2800 lm we need 300,000 lumens divided by 2800 lumens = 107 lamps. Each 8’ fixture contains 4 lamps so we need 27 fixtures. In math terms this takes the form:

    # fixtures = (desired fc) x (shop area) x (2) / (lumens per lamp) x (# lamps per fixture)
    = (100 fc) x (1500 sq. ft.) x (2) / (2800 lumens) x (4) = 27 fixtures
    How will that fit into the space? If we mount the fixtures end to end in continuous rows we can fit 6 fixtures in a row with one foot left over at each end. In reality a 50’ long building won’t have 50’ of free space inside since the walls take up some of that 50’ so 6 fixtures is a good fit. The next question is how many rows. Twenty seven fixtures divided by 6 = 4.5 rows. We can’t realistically install half a row so we have a choice of 4 or 5 rows. Before making that choice let’s see how they might fit in the space.

    Good design practice calls for spacing rows even distances apart with the distance from the walls to the closest row 1/3 to ½ the spacing between rows. I usually calculate it for ½ and make adjustments if needed later. For the first option, 4 rows, divide the total distance, 30’ for the example, by the number of rows, so 30/4 = 7.5 feet. This is the spacing between rows and the spacing from a wall to the first row is ½ that, or 3’8”. The 3’8” will actually be less, closer to 3’ due to wall thickness but that’s ok. It’s a good idea to have some fixtures close to walls because we frequently put machines long them. That’s where the electrical outlets usually are. The other option is to use 5 rows spaced 6’ apart and located about 3’ from the walls. The layouts are shown in Figure 6.



    Figure 6. Two possible layouts for the example shop. Option 1 is uses fewer fixtures and will result in substantial savings in both first cost and ongoing O & M costs. It will, however, require occasional cleaning of fixtures to maintain lighting levels.


    When determining the spacing it’s a good idea to avoid unusual distances such as 7’ 2 ¾”. Just round it to 7’ and make adjustments next to the walls.

    The next step is to see if the layouts meet the criteria for providing uniform lighting without dark spots in between fixtures. That’s done using something called the spacing criteria, or SC. It provides the maximum spacing between fixtures for uniformity based on the mounting height of the fixtures above the work surface. It is found from manufacturer’s catalogs or specification sheets and is given as two values, one for spacing parallel to the lamps, and one for perpendicular. We are mounting the fixtures in continuous rows so we need be concerned only with the perpendicular spacing. Since you probably won’t have access to the data, values of 1.5 perpendicular and 1.3 parallel are reasonable assumptions.

    For the example we have a 10’ ceiling. Most workbenches or tables are about 3’ high so the mounting height above the work plane is 7 feet. The maximum spacing is then 1.5 x 7’ = 10.5 feet. Both of our proposed layouts use closer spacing so either is acceptable in terms of uniformity. It is important to understand that the spacing criteria are not a design guide to determine optimum spacing. It is only used to determine the maximum spacing to achieve a uniform distribution of light within the space.

    Note that this example assumes fixtures will be mounted in continuous rows. This is generally the preferred method since it provides good light distribution and minimizes electrical wiring costs since the fixtures themselves are used as the raceway and it is only necessary to provide power to one end of the row. An exception might be when lower lighting levels are desired and fewer fixtures are needed.

    We are now at a decision point. The estimate calls for 27 fixtures but that doesn’t fit well into the space. Option 1 calls for 24 fixtures while the other calls for 30. Do we put in 3 too many or 3 too few. I’d go with 24. There’s a considerable savings in first cost and ongoing costs for electricity, and fewer replacement lamps over time. We can easily maintain the lighting levels we want by occasionally cleaning the lamps and fixtures. That’s because we factored in a decline in light output due to dirt accumulation on the lamps and fixtures, and the gradual depreciation in light produced by the lamps. These losses can be recovered by cleaning and relamping. Routine cleaning once every year or two will help maintain lighting levels in your shop. Note that when the system is new and everything is clean the lighting levels will be higher than the design level. That’s normal.

    The information provided in this paper can’t cover all of the possible configurations of shops or all of the various tasks we perform in them, but it does contain guidelines that should be of help for most of them.


    Acknowledgments


    In closing it is only proper to thank those who have been involved in bringing the idea to print. To Ken Fitzgerald, Forum Moderator, for his tireless efforts to overcome limitations on posting long articles on the Forum and taking the lead in the actual posting. This article would not be on the Forum without Ken’s considerable efforts. To Michael Mayo for lending his IT expertise, to Jim O’Dell for suggesting in the beginning that I write it, and to Dave Anderson, another Forum Moderator, for jumping in at the start to suggest how it might be done. And thanks to all of them for reviewing and commenting on the content and format. Finally, a big thanks to the Illuminating Engineering Society of North America for providing most of the illustrations.

    This article was originally published in forum thread: Lighting the Small Workshop - by Jack Lindsey started by Jack Lindsey View original post
    Comments 89 Comments
    1. Ken Fitzgerald's Avatar
      Ken Fitzgerald -
      Mike,

      I couldn't agree more! It's one of those situations a person has to experience for themself to fully appreciate. But when the lighting is properly designed and executed, it is a wonderful thing in which to work!
    1. Steve Strobel's Avatar
      Steve Strobel -
      Quote Originally Posted by Ken Fitzgerald View Post
      Steve...My shop is 30'x24' with 10' ceilings. I used Jack's original article to design my lighting.

      I placed 4 rows of 8' T-8 , 4 bulb fixtures. There are 3 rows of 3, 8' fixtures and 1 row of 2, 8' fixtures for a total of 44 bulbs. I eliminated 1, 8' fixture because it would been too close to my hanging gas furnace and I was sure that would be a problem in the fall, winter and early spring.

      Each row has its own switch. So I turn on only what I need and yet, I can light the entire shop when I desire.

      Everybody who has come into the shop has commented positively about the lighting and it works well with my 60 year old eyes.
      Sorry for the slow reply. Thanks for the input. I've decided to run 5 rows (24' width), each row containing 2-8' fixtures and 1-4' fixture. This should give me great lighting. I do plan on switching each row for the best control. Thanks again. Steve
    1. Steve Milito's Avatar
      Steve Milito -
      Quote Originally Posted by Ken Fitzgerald View Post
      Tom,

      In the example he's using 4 32watt T-8 - 4' bulbs watt in 8' fixtures and from the article:

      The footcandle was previously defined as lumens of light per square foot. To provide 100 footcandles we need 100 lumens per square foot times 1500 square feet, or 150,000 lumens at the work surface. Since only half of the lumens on the ceiling make it down to the work surface we need twice as many on the ceiling, or 300,000 lm. Assuming a 32w T8 lamp rated at 2800 lm we need 300,000 lumens divided by 2800 lumens = 107 lamps. Each 8’ fixture contains 4 lamps so we need 27 fixtures. In math terms this takes the form:



      # fixtures = (desired fc) x (shop area) x (2) / (lumens per lamp) x (# lamps per fixture)
      = (100 fc) x (1500 sq. ft.) x (2) / (2800 lumens) x (4) = 27 fixtures

      He's talking 100 lumens/ sq. ft. at the work surface not at the light fixture.


      In googling around it seems 8' T8 lamps are 5000 - 6000 lumens. Thus, it appears to me that you need 27 fixtures if you go with 4' fixtures, or 1/2 that number if you go with 8' fixtures.
    1. Jack Lindsey's Avatar
      Jack Lindsey -
      Quote Originally Posted by Steve Milito View Post
      In googling around it seems 8' T8 lamps are 5000 - 6000 lumens. Thus, it appears to me that you need 27 fixtures if you go with 4' fixtures, or 1/2 that number if you go with 8' fixtures.
      Steve - the example is based on 8' fixtures with four 4' lamps per fixture. One 8' lamp will produce about the same number of lumens as two 4' lamps so an 8' fixture with two 8' lamps will produce about the same lighting level as an 8' fixture with four 4' lamps. You will still need 27 fixtures. If you are thinking of using 8' fixtures with four 8' lamps per fixture then you could reduce the number of fixture by 50% but that will require a different mounting arrangement and you may affect the performance of the system and significantly increase the installation cost.
    1. Steve Milito's Avatar
      Steve Milito -
      Ahh, I didn't get the 4 x 4' lamps in an 8' fixture.
      I am planning a shop of about the same size, when I googled to find a source for fixtures I could not find 4 x 4' fixtures anywhere, but found plenty of 4 x 8' industrial fixtures. I wrongfully assumed you we using the 4 x 8' fixtures.
      Thanks for the great article.
    1. Jack Lindsey's Avatar
      Jack Lindsey -
      Quote Originally Posted by Steve Milito View Post
      Ahh, I didn't get the 4 x 4' lamps in an 8' fixture.
      I am planning a shop of about the same size, when I googled to find a source for fixtures I could not find 4 x 4' fixtures anywhere, but found plenty of 4 x 8' industrial fixtures. I wrongfully assumed you we using the 4 x 8' fixtures.
      Thanks for the great article.
      Your welcome, Steve. Glad you found it useful.
    1. John F. Gates's Avatar
      John F. Gates -
      Jack, you help in the original article in FWW was awesome and your further help to all of us is very much appreciated! I've just relocated from Alaska to Western NC and am setting up my shop in a 3 car garage (it is 35' wide X 25' deep). I'm using 2 of the bays and my shop will be 24' wide by 25' deep. The 24' wide area has 2- 10' garage doors that I'm hoping will be open a lot down here (thankfully)!

      Do you have any suggestions on lighting ideas for garages with garage doors open (under the open garage doors). I've placed my main bench and saws away from the doors (opposite end of the shop) - and will focus my lighting on those areas.

      I'll do my best and attach a photo of a rough shop drawing. The garage doors are at the bottom of the photo.

      Appreciate the help!

      John
      [IMG]Gates Shop.jpg[/IMG]
    1. John F. Gates's Avatar
      John F. Gates -
      Jack, here is another shot at adding my shop drawing.Attachment 240493
    1. Jack Lindsey's Avatar
      Jack Lindsey -
      Thanks for your comments, John. It's good to know that the articles are useful. Unfortunately in this case I'm not going to be much help. Other than locating the major work areas away from the doors there really isn't much else that will help. The doors will block light. Painting the walls and the inside of the doors white will help a little. If the doors have windows you can locate fixtures above the windows so they will shine through the glass, but really not a perfect solution but better than nothing. On the plus side you should get quite a bit of light in through the door openings when the doors are up, and locating fixtures on the ceiling above the open doors will provide light when the doors are closed. Your layout looks similar to the one I had in the garage before building my dedicated shop. I opened the doors during the day and had no problems. Hope that works ok for you. Please let me know if you find a better solution.
    1. John F. Gates's Avatar
      John F. Gates -
      Thanks Jack. I'll do just what you've suggested - mount the lights as if there were no doors and then when they are open, I'll enjoy the natural light from outside.

      Another note, I've got 7 - 8' 2 bulb (16 - 4' sections joined together) and then 8 - 4' 3 bulb fixtures. They are all T-8's. So, I'll just install them across the workspace accordingly. In the past, I've installed 2 - 8' sections close together above the bench for additional light, but you don't suggest this in your article. Rather, always the layout is systematically proportioned to the space. Interesting.

      Again, thanks for the help.

      John
    1. Jack Lindsey's Avatar
      Jack Lindsey -
      Quote Originally Posted by John F. Gates View Post
      Thanks Jack. I'll do just what you've suggested - mount the lights as if there were no doors and then when they are open, I'll enjoy the natural light from outside.

      Another note, I've got 7 - 8' 2 bulb (16 - 4' sections joined together) and then 8 - 4' 3 bulb fixtures. They are all T-8's. So, I'll just install them across the workspace accordingly. In the past, I've installed 2 - 8' sections close together above the bench for additional light, but you don't suggest this in your article. Rather, always the layout is systematically proportioned to the space. Interesting.

      Again, thanks for the help.

      John
      John, there's a couple of reasons why I recommend uniform lighting systems for small shops. First, the spaces aren't really large enough to benefit from task oriented lighting fluorescent systems since the task areas are close together and the light distribution characteristics of the fixtures cover fairly wide areas. Secondly, in a small shop the work areas move about frequently and we are likely to perform seeing tasks at virtually any location in the shop.
    1. Jim O'Dell's Avatar
      Jim O'Dell -
      Was I whining??? RRREEEEEAAAALLLLLLYYYYYY?????? If that was whining, then it looks like it worked!!! Thanks Ken for the extra effort to get the calculator to work within the confines of the software. It looks like several people used it judging from the comments. It's also obvious I haven't looked in on this thread in a long long time. I'm super happy that so many have benefited from the work that Jack put in on it. Jim.



      Quote Originally Posted by Ken Fitzgerald View Post
      Jim....this version of VBulletin won't allow Microsoft Excel ".xlsx" extention files to be upload. However, I did a little research and found out how to save Jack's calculator as a ".xls" file.
      So here is Jack's calculator:

      Attachment 232593
    1. Ken Fitzgerald's Avatar
      Ken Fitzgerald -
      Quote Originally Posted by jim o'dell View Post
      was i whining??? Rrreeeeeaaaallllllyyyyyy??????:d if that was whining, then it looks like it worked!!! Thanks ken for the extra effort to get the calculator to work within the confines of the software. It looks like several people used it judging from the comments. It's also obvious i haven't looked in on this thread in a long long time. I'm super happy that so many have benefited from the work that jack put in on it. Jim.
      :d:d:d:d
    1. Tom VanDenEng's Avatar
      Tom VanDenEng -
      Thanks for the great article, there is diffidently alot more to proper shop lighting then I thought
    1. Richard Demaray's Avatar
      Richard Demaray -
      It's good to see the interest in lighting from other woodworkers. Other articles or comments might expand or add information about color rendering index, color temperature, day-lighting and cost and recommendations for particular lighting products. I recently received a light therapy light which is wonderfully bright and added it to the sources over and around my work bench. It is like working in the best sunlight I can imagine, not to bright or hot but wonderfully clear like the sun through a frosted glass overhead and also no shadow. I plan to bring home a LUX meter and see what kind of 'therapy' it is that I'm enjoying. I can see very clearly light traces from my marking knife and I think I have less eye strain.

      I'm work daily with what might be of interest once the general illumination requirements are established. I just attended the DOE Solid State Lighting Conference in Long Beach in early February and the presentation for that meeting should be available any day now. You might not want to dive down into the deep end of that pool, but more than half was dedicated to information that is directly intended to help regular consumers and manufacturers of high efficiency and high quality lighting make good choices with new and recently tested products that are now for sale. See

      http://www1.eere.energy.gov/building...entations.html

      for the latest videos, webinars, publications and presentations on product performance, selection, efficiency, quality, reliability, and cost effectiveness, updates on Lighting Facts, CALiPER testing and demonstrations of the bulbs and fixtures you can choose from the store today. Several years ago, many LED and other lights didn't test up to the label but now many do and some exceed performance specifications. It's paid for with our taxes and IMHO a great bargain for those looking for sensible practical information to help guide a purchase.

      Even though I work on the technical side, I'm also a wood worker with a garage shop that is begging for some better lighting. And even though I work in the OLED and LED solid state areas, there is quite ready information of fluorescent and induction lighting choices which are quite competitive, particularly if you are like me and sensitive to the purchase price. The fluorescent tube is not setting still and is giving LEDs etc. a very good run for the money, even in energy efficiency, lifetime, cost of electricity, heat load, etc. LA has saved a huge amount of money and will soon have installed 140 thousand LED streetlights. Sacramento did the same math and picked non-solid state street lights. So there is a horse race where we are the winners!

      Last, no discussion is complete without just a mention to look up or evaluate the color temperature, color rendering index, reliability and cost of the products you can choose. I'm looking for 3000 Kelvin or higher, a CRI of at least 81 and have found many products to install with a cost less than $10/meter sq. I put in a double glass door and a new garage door with "lights" along the top for more day light, but a sky light and a window are on my shopping list. Cheers
    1. george newbury's Avatar
      george newbury -
      Is it now time to bring into this great discussion LED?

      I just saw where HD is selling a 2' x 2' LED that someone says puts out 11,000 lumens. I've an RV shed that could use 50 to 100 lumens and presently has 8' T12's whose ballasts are going.

      I was planning on putting up t5's but lower maintenace LED's might make the cost tradeoff worthwhile.
    1. Eric DeSilva's Avatar
      Eric DeSilva -
      Interesting--here's the link to HD's site: http://www.homedepot.com/p/t/2038127...0#.UbIIYJyv_5E. 11.2K lumens in a 5" x 15" x 23" package for $199. It would take two ($400) to get to the same light (more or less) than the 4xT5HO package they have at ~$120 with bulbs. HD estimates the yearly cost of a T5HO at $6.50, so $26 v. $18 (based on the LEDs being 31% more efficient). Even if you have to replace the T5HOs once (they have 1/2 the est. life of the LEDs), my quick math suggests a 14 year pay-off v. T5HOs. Still, that is a lot of progress. The math could be a lot different in a year or two.
    1. Jack Lindsey's Avatar
      Jack Lindsey -
      While LED luminaires have undergone significant technological improvements during the past year they are still much more expensive than conventional T-8 strips. The LED fixture cited in the post costs $219 compared to about $40 for a 4 lamp strip that produces about the same lumens. LED's are improving and at some point they will be competitive for small shops but that day is still in the future.
    1. Jeff Erbele's Avatar
      Jeff Erbele -
      Thanks for the great article. I am new to SMC and discovered it while exploring this site. It was a timely find as we are building a new house with a dedicated shop area in the 4 bay attached garage. Two bays are 20' x 20' and the adjacent dedicated shop area is 20' x 30'. Thirty some years ago when I built my first workshop 24' x 24', I was clueless regarding lighting requirements. My solution was to wire rows of switched outlets on the ceiling. Back then, a basic hanging T-12 shop light with reflector, with two 4' 40 watt lights retailed for $10. I hung them all over the place and turned on as many as needed. Call it the trial with room for expansion method. While it worked, I would rather design a proper lighting system upfront. Your article solves that, providing the basic information required.
    1. Jon Murphy's Avatar
      Jon Murphy -
      I'm very late reading this excellent article, but would like to make a few comments on my own solution to the small shop. Mine is a very small shop, it is in my bedroom. The bedroom is 12 x 15' and basically divided in half diagonally as shop and living quarters (bed, bookshelves, desk, etc.). I mainly do wood turnings, but also some other work. The equipment is a lathe, a grinding station, a band saw, a drill press, and a small belt/disc sander. There is also a 5' work bench.

      As it is a bedroom in an apartment I really can't light the whole shop with ceiling fixtures so I took an alternate route. I have two industrial fixtures (paired 4' T8 lights) suspended on pulleys from the ceiling. One is over the workbench and the other over the lathe. As an old sailorman I've set them up with a double pulley and a single one so that the lines to each end of the fixture are paired and can be pulled together - they are cleated down on the wall. That way I can raise or lower them at will (convenient also for changing bulbs - I'm 78 and on one leg). The band saw and drill press each have their own goose neck fixtures, and I've installed one over the grinding station as well as another on a rolling table that is the storage for my lathe tools. I use that one to give me a horizontal light when hollowing bowls.

      In no way is this a contradiction of the article, it is an alternate solution for those who may not be able to either afford or install full shop lighting. Oops, I forgot something. My sanding and finishing station is a folding work table (B & D Workmate) in the "living half" of the room. I put a triple spot strip fixture on the wall to light it. It is energy inefficient but I only use it when off lathe sanding or finishing.

      Thank you for the article, it was very informative for me as to the terminology - I've been going "by guess and by golly" in selecting bulbs and understanding what the new regulations will allow us to buy. I'd be interested in learning about the kinds of "spot lamps" that will be available for standard sockets as I use them for local lighting.