PDA

View Full Version : Dust Collection for CNC Question



Greg Parrish
10-29-2019, 6:16 PM
I know this typically would be discouraged as being too close to the cyclone, but would it work if I put a wye in the pipe right above and right of the CNC to install a gate for the CNC line? I have amazing suction and dust collection at all drops so wouldn’t want a wye here to cause disruption due to turbulence. Just curious on thoughts as this seems to be the easiest place for me to tap into my system and get a pickup for the new CNC. Thanks for your input. Greg



418510

418509
Sorry, not sure why it turned sideways.

Jim Becker
10-29-2019, 8:15 PM
There's no harm in a little bit of flex back to the CNC so I'd put the drop for it well beyond the last few feet of the inlet to the cyclone. In fact, you need a bit of flex and a, um...flexible way to hang it...over the CNC so it can move with the gantry and not get hung up.

While my space and machine is different, the general idea you see here is very workable in your shop...

https://g9qybw.dm.files.1drv.com/y4mD0GgGNxrQ2KJELPKdT-cHUEn0FMastojqUopaazsqEpVbM_Vw5mgi0Jo-Ptqm-tmjLYeS7qn-JtmPZbJuWxu6yHosv9k4sU76Q2Akg_aMdfHmNInwbuyf0UjZC5 y3sOH59Ys9fIh_LSnL5Q8eezwDzFMG9bAEu-0bf6Us6uQI-AX5hdm2QDupSF-eHJ5XeCsrYlNMEAurYBVBG9RZpn-2g?width=495&height=660&cropmode=none

Greg Parrish
10-29-2019, 8:23 PM
oh i plan to have flex tube but im limited on ways to tap into the existing duct work. thats why i was wondering if it would be a bad idea to tap in with a wye right near the cyclone. ill plan to look at one of the other spots. thanks

Tom Bain
10-29-2019, 9:50 PM
There's no harm in a little bit of flex back to the CNC so I'd put the drop for it well beyond the last few feet of the inlet to the cyclone. In fact, you need a bit of flex and a, um...flexible way to hang it...over the CNC so it can move with the gantry and not get hung up.

While my space and machine is different, the general idea you see here is very workable in your shop...


Jim — What size wye and flex duct are you running to spindle? Curious what is recommended for optimal extraction.

Jim Becker
10-30-2019, 9:10 AM
Jim — What size wye and flex duct are you running to spindle? Curious what is recommended for optimal extraction.

My duct work at that point in the shop (near the end of the line) is 4" and that's what goes to the CNC. (Main from the cyclone is 7" which steps down to 6" for most of the network with the majority of drops at 5") The Kent Dust Shoe is designed for 4". Do note that this is the ONE tool that you have to be absolutely sure that the duct work/hose is properly grounded. Gary Campbell has an excellent YouTube video about that. Things can get really wonky on a CNC if there is even the slighted bleed of static electricity because of the nature of the electronics.

Jim Becker
10-30-2019, 9:12 AM
oh i plan to have flex tube but im limited on ways to tap into the existing duct work. thats why i was wondering if it would be a bad idea to tap in with a wye right near the cyclone. ill plan to look at one of the other spots. thanks

Personally, I wouldn't want to disturb the air flow that close to the cyclone. I'd do the drop beyond as noted in my previous. But that's me...

Greg Parrish
11-03-2019, 7:12 PM
So I emailed with Oneida Air Systems and they said it should be no problem adding in the wye. So, spent some time this weekend getting it all done. Just need to add a light over the CNC now and it is done.

418904
418906

Not sure why my photos from the iPhone are turning sideways when they are in portrait orientation. Frustrating. Hopefully you can tell what I ended up with by turning your head a little left. LOL

Jim Becker
11-03-2019, 7:16 PM
You're pretty much ready to rock 'n roll!

Greg Parrish
11-03-2019, 7:25 PM
You're pretty much ready to rock 'n roll!


Yes sir. I was going to get it fired up today but spent the day finalizing the dust piping and then merging my festool vac into my armor bench. I made a separate post about that project. LOL

Carl Beckett
11-08-2019, 6:07 PM
My duct work at that point in the shop (near the end of the line) is 4" and that's what goes to the CNC. (Main from the cyclone is 7" which steps down to 6" for most of the network with the majority of drops at 5") The Kent Dust Shoe is designed for 4". Do note that this is the ONE tool that you have to be absolutely sure that the duct work/hose is properly grounded. Gary Campbell has an excellent YouTube video about that. Things can get really wonky on a CNC if there is even the slighted bleed of static electricity because of the nature of the electronics.

Are the Festool vac hoses grounded?

Jim Becker
11-08-2019, 9:00 PM
Are the Festool vac hoses grounded?
They have both anti-static and non-anti-static versions; the ones that come with the extractors are anti-static...which is the only ones I'd use. It's no fun getting "zapped"!!! But relative to dust collection for a CNC, it's pretty much "mandatory" to be sure there is proper grounding formally because even the tiniest amount of static electricity can make for very wonky things happening.

Tom Bender
11-16-2019, 7:36 AM
That will work fine but a 6 x 6 x 4 wye would have caused slightly less disturbance to the main line, if you could have found one.

Congrats on the new toy.

Greg Parrish
11-24-2019, 12:55 PM
Suction working just fine. Finally making my inaugural cut with the CNC. Wow what a learning curve to get going. LOL

also attached pic showing ground wire discussed above. Grounded back to dust collector.

420197

420196

Jim Becker
11-24-2019, 9:31 PM
Looking good, Greg. Yes, there's a learning curve. But you can add complexity in tiny increments while you build the necessary "every job" habits. I started just like in your photo. A very simple sign. And then the same simple sign with some additional thing added. Rinse, repeat...and now I can even spell "CNC" a year and a half later. :) :D