PDA

View Full Version : Just received the upgrade DVR for Nova 1624-44



Roger Davis TN
04-04-2019, 1:00 AM
Does anyone know past the supplied manual how to take advantage of all the features of this motor? I am trying to get Nova and the manufacture to send a comprehensive manuel to operate this motor. So far it seems no one wants to send me more information. There is a stepping function and a screen that follows that is Greek to me" What the heck does ktint+/-kprop mean." For example. There is much more I do not understand. Please help me, Roger.

Harold Walsh
04-04-2019, 9:56 PM
I just replied to your question on my post, I too am puzzled about some of these functions ?

Allan Ferguson
04-06-2019, 9:39 PM
Roger, sent a P M, or at least tried to.

Bill Boehme
04-06-2019, 11:20 PM
What the heck does ktint+/-kprop mean." For example. There is much more I do not understand.

Those are gain constants for the PID controller. Ktint is the integral time constant gain and Kprop is the control system proportional gain constant. These parameters optimize the control system for the best response to a step input with minimum overshoot. Now that you know, hopefully you also know not to monkey around with those parameters. At best, changing these parameters would degrade system performance. At worst, changing these parameters could make the system either unstable or non functional.