PDA

View Full Version : DW735 and dust duct size



Rick Moyer
11-22-2010, 6:19 PM
I'm getting ready to plumb the shop (finally) for dust collection and I know I should run 6" as far as I can, BUT, I'm thinking 4" is enough for this tool. If I turn it on it will blow up the single stage Delta I have without the Delta even on! I'm thinking the chip blower will provide adequate force in conjunction with a 4" flex to get everything into the mainstream 6" ducting to the cyclone.
Your thoughts....

keith micinski
11-22-2010, 6:22 PM
I have a 4" port connected to mine and it does just fine. It doesn't get 100 percent but I think because of the size of the opening of the planer any size hose would miss a little.

Dan Friedrichs
11-22-2010, 7:30 PM
Yep. The thing actually only has like a 2.5" outlet, but that adapter brings it up to 4". I run 4" to it, and it's fine - 6" definitely would not help, considering the very small size of the opening.

Myk Rian
11-22-2010, 8:33 PM
I run 4" all the way to the DC with a trash can separator in-line. It gets everything the planer produces, except for a little at the in and out feeds.
Nature of the beast.